Data Table
PARAMETER | Test condition | Min. | Typ. | Max. | Units |
---|---|---|---|---|---|
INSERTION LOSS | 20 MHz 8 GHz |
0.3 2 |
dB | ||
RETURN LOSS | 20 MHz – 8 GHz | 10 | 20 | dB | |
CW INCIDENT POWER | 20 MHz – 8 GHz Tcase=85ºC |
44 (22) | dBm (W) | ||
PEAK INCIDENT POWER | 20 MHz – 8 GHz PW=1 µs, DC=0.1% |
51 (125) | dBm (W) | ||
CW FLAT LEAKAGE | 20 MHz – 8 GHz Pin=30 dBm Pin=44 dBm |
17 16 |
dBm | ||
PULSED FLAT LEAKAGE | 20 MHz – 8 GHz Pin=50 dBm, PW=1 µs, DC=0.1% |
20 | dBm | ||
RECOVERY TIME | 20 MHz – 8 GHz | 500 | ns | ||
IP1dB | 20 MHz – 8 GHz | 8 | dBm | ||
IN/OUT DC BLOCKING | NO | ||||
SIZE | 35 × 45 × 15 | mm | |||
CONNECTOR IN | SMA (F) | ||||
CONNECTOR OUT | SMA (F) |
Environmental Ratings
TEMPERATURE: | -40ºC TO +85ºC (OPERATING) -55ºC TO +125ºC (STORAGE) |
HUMIDITY: | MIL-STD-202G, METHOD 103B COND. B |
SHOCK: | MIL-STD-202G, METHOD 213B COND. B |
VIBRATION: | MIL-STD-202G, METHOD 204D COND. B |
ALTITUDE: | MIL-STD-202G, METHOD 105C COND. B |
TEMP. SHOCK: | MIL-STD-202G, METHOD 107D COND. A |