Data Table
| PARAMETER | Test condition | Min. | Typ. | Max. | Units |
|---|---|---|---|---|---|
| INSERTION LOSS | 0.1 – 20 GHz | 1.5 | dB | ||
| VSWR | 0.1 – 20 GHz | 1.6:1 | 1.8:1 | ||
| CW INCIDENT POWER | 0.1 – 20 GHz 25ºC |
33 (2) | dBm (W) | ||
| PEAK INCIDENT POWER | 0.1 – 20 GHz PW=100 µs, DC=10%, 25ºC |
40 (10) | dBm (W) | ||
| CW FLAT LEAKAGE | 0.1 – 20 GHz Pin=33 dBm 25ºC |
19 | dBm | ||
| PULSED FLAT LEAKAGE | 0.1 – 20 GHz Pin=40 dBm, PW=100 µs, DC=10%, 25ºC |
20 | dBm | ||
| RECOVERY TIME | 0.1 – 20 GHz | 40 | ns | ||
| SIZE | ø10.25 x 35.1 | mm | |||
| CONNECTOR IN | SMA (M) | ||||
| CONNECTOR OUT | SMA (F) |
Environmental Ratings
| TEMPERATURE: | -40ºC TO +85ºC (OPERATING) -55ºC TO +125ºC (STORAGE) |
| HUMIDITY: | MIL-STD-202G, METHOD 103B COND. B |
| SHOCK: | MIL-STD-202G, METHOD 213B COND. B |
| VIBRATION: | MIL-STD-202G, METHOD 204D COND. B |
| ALTITUDE: | MIL-STD-202G, METHOD 105C COND. B |
| TEMP. SHOCK: | MIL-STD-202G, METHOD 107D COND. A |