Data Table
PARAMETER | Test condition | Min. | Typ. | Max. | Units |
---|---|---|---|---|---|
INSERTION LOSS | 1 GHz 4 GHz |
0.6 1 |
1.15 | dB | |
RETURN LOSS | 1 – 4 GHz | 15 | 18 | dB | |
CW INCIDENT POWER | 1 – 4 GHz Tcase=85ºC |
50 (100) | dBm (W) | ||
PEAK INCIDENT POWER | 1 – 4 GHz PW=25 µs, DC=5% |
60 (1) | dBm (kW) | ||
CW FLAT LEAKAGE | 1 – 4 GHz Pin=35 dBm Pin=50 dBm |
15 7.5 |
dBm | ||
PULSED FLAT LEAKAGE | 1 – 4 GHz Pin=60 dBm, PW=25 µs, DC=5% |
15 | dBm | ||
RECOVERY TIME | 1 – 4 GHz | 3 | µs | ||
IP1dB | 1 – 4 GHz | 9 | dBm | ||
IN/OUT DC BLOCKING | YES | ||||
SIZE | 50 × 35 × 15 | mm | |||
CONNECTOR IN | SMA (F) | ||||
CONNECTOR OUT | SMA (F) |
Environmental Ratings
TEMPERATURE: | -40ºC TO +85ºC (OPERATING) -55ºC TO +125ºC (STORAGE) |
HUMIDITY: | MIL-STD-202G, METHOD 103B COND. B |
SHOCK: | MIL-STD-202G, METHOD 213B COND. B |
VIBRATION: | MIL-STD-202G, METHOD 204D COND. B |
ALTITUDE: | MIL-STD-202G, METHOD 105C COND. B |
TEMP. SHOCK: | MIL-STD-202G, METHOD 107D COND. A |