Data Table
PARAMETER | TEST CONDITION | MIN. | TYP. | MAX. | UNITS |
---|---|---|---|---|---|
INSERTION LOSS | 0.5 GHz 4 GHz | 0.4 1 | 1.25 | dB | |
RETURN LOSS | 0.5 GHz - 4 GHz | 12 | 16 | dB | |
CW INCIDENT POWER | 0.5 GHz - 4 GHz Tcase=85ºC | 53 (200) | dBm (W) | ||
PEAK INCIDENT POWER | 0.5 GHz - 4 GHz PW=25 µs, DC=5% | 63 (2) | dBm (kW) | ||
CW FLAT LEAKAGE | 0.5 GHz - 4 GHz Pin=30 dBm Pin=45 dBm | 15 20 | dBm | ||
PULSED FLAT LEAKAGE | 0.5 GHz - 4 GHz Pin=63 dBm, PW=25 µs, DC=5% | 17 | dBm | ||
RECOVERY TIME | 0.5 GHz - 4 GHz | 1.5 | µs | ||
IP1dB | 0.5 GHz - 4 GHz | 10 | dBm | ||
IN/OUT DC BLOCKING | YES | ||||
SIZE | 35 × 50 × 15 | mm | |||
CONNECTOR IN | SMA (F) | ||||
CONNECTOR OUT | SMA (F) |
Environmental Ratings
TEMPERATURE: | -40ºC TO +85ºC (OPERATING) |
-55ºC TO +125ºC (STORAGE) | |
HUMIDITY: | MIL-STD-202G, METHOD 103B COND. B |
SHOCK: | MIL-STD-202G, METHOD 213B COND. B |
VIBRATION: | MIL-STD-202G, METHOD 204D COND. B |
ALTITUDE: | MIL-STD-202G, METHOD 105C COND. B |
TEMP. SHOCK: | MIL-STD-202G, METHOD 107D COND. A |